What kind of RTD cables & PRT cable do you need?

RTD Cables & PRT Cable

Resistance Temperature Detectors (RTDs) and Platinum Resistance Detectors (PRTs) offer an alternative measurement technology to thermocouples and are generally used at extreme temperatures. RTDs are used because of their simpler operation, increased stability and sensitivity although they have an increased response time. PRTs measure temperature by determining the electrical resistance of a piece of pure platinum wire.

Heatsense offers a variety of RTD and PRT extension cables available in 2, 4 or 6 core configurations and sheathed in PFA, PTFE, ETFE, FEP or PVC to suit a variety of applications.

RTD Cables

RTDs

Product info

  • Available in a variety of lengths
  • 2, 4 or 6 core
  • Can be sheathed in PFA, PTFE, ETFE, FEP or PVC

PRTs

Heatsense supplies 7/0.2mm diameter copper stranded conductors that can be provided stranded, screened or unscreened for use with PRT sensors. Available in 2, 4 or 6 core configurations and sheathed in PFA, PTFE, ETFE, FEP or PVC to suit a variety of applications.

  • Red or White inner insulation
  • PVC and PVC screened insulation rating -10°C ~ +105°C
  • PFA and PFA screened and PTFE and PFA screened insulation rating -75°C ~ +260°C
  • Available incorporating tin-plated copper, stainless steel- or nickel-plated over-braid
  • Available in a variety of lengths

PRT Twisted Pairs

Heatsense supplies 7/0.2mm diameter copper stranded conductors. Two or four cores are supplied and insulated in PFA. The cores are then twisted and over-sheathed in a PFA jacket.

  • Copper stranded conductors
  • PFA insulated
  • Red or White Colour Code
  • Insulation rating -75°C ~ +260°C
  • Available in a variety of lengths
Part No Conductor Material Construction Colour Code Specification
SPCF1921 Silver Plated Copper Each Core Glass Fibre Insulated Twisted Glass Fibre sheath with Stainless Steel Overbraid 4 x Red 2 x White Overall White Sheath N/A
Insulation Number of cores Number of strands Conductor size (mm) Cross section area (mm²) Nominal overall diameter (mm) Insulation temperature rating (°C) Voltage rating Current rating Conductor resistance (Ohms/km @ 20°C)
Glass Fibre and Stainless Steel 6 19 (AWG 20) 0.2 0.597 4.6 Nominal -75 to + 200 240 11 Amps @ 40° C Ambient In Free Air
Part No SPCF1921
Conductor Material Silver Plated Copper
Construction Each Core Glass Fibre Insulated Twisted Glass Fibre sheath with Stainless Steel Overbraid
Colour Code 4 x Red 2 x White Overall White Sheath
Specification N/A
Insulation Glass Fibre and Stainless Steel
Number of cores 6
Number of strands 19 (AWG 20)
Conductor size (mm) 0.2
Cross section area (mm²) 0.597
Nominal overall diameter (mm) 4.6 Nominal
Insulation temperature rating (°C) -75 to + 200
Voltage rating 240
Current rating 11 Amps @ 40° C Ambient In Free Air
Conductor resistance (Ohms/km @ 20°C)
SPCF7152 Silver Plated Copper Single Core Double Glass Fibre Lapped and Braided White N/A