Part No Conductor Material Construction Colour Code Specification
TPCA19237 Tinned Plated Copper Each Core PFA Insulated Type B Twisted With My-AL Screen + A 19 x 0.2 mm Drain Wire and PFA Sheath Overall As Required Generally In Accordance to BS3G210
Insulation Number of cores Number of strands Conductor size (mm) Cross section area (mm²) Nominal overall diameter (mm) Insulation temperature rating (°C) Voltage rating Current rating Conductor resistance (Ohms/km @ 20°C)
PFA 2 19 (AWG20) 0.2 0.597 4.2 Nominal - 75 to +180 600 11 Amps @ 40° C Ambient In Free Air Derating Factor of 0.8 to Be Applied For 2 Core Cable
Part No TPCA19237
Conductor Material Tinned Plated Copper
Construction Each Core PFA Insulated Type B Twisted With My-AL Screen + A 19 x 0.2 mm Drain Wire and PFA Sheath Overall
Colour Code As Required
Specification Generally In Accordance to BS3G210
Insulation PFA
Number of cores 2
Number of strands 19 (AWG20)
Conductor size (mm) 0.2
Cross section area (mm²) 0.597
Nominal overall diameter (mm) 4.2 Nominal
Insulation temperature rating (°C) - 75 to +180
Voltage rating 600
Current rating 11 Amps @ 40° C Ambient In Free Air Derating Factor of 0.8 to Be Applied For 2 Core Cable
Conductor resistance (Ohms/km @ 20°C)